Python netsnmp oid

CPU Statistics

Load
1 minute Load: .1.3.6.1.4.1.2021.10.1.3.1
5 minute Load: .1.3.6.1.4.1.2021.10.1.3.2
15 minute Load: .1.3.6.1.4.1.2021.10.1.3.3

CPU
percentage of user CPU time: .1.3.6.1.4.1.2021.11.9.0
raw user cpu time: .1.3.6.1.4.1.2021.11.50.0
percentages of system CPU time: .1.3.6.1.4.1.2021.11.10.0
raw system cpu time: .1.3.6.1.4.1.2021.11.52.0
percentages of idle CPU time: .1.3.6.1.4.1.2021.11.11.0
raw idle cpu time: .1.3.6.1.4.1.2021.11.53.0
raw nice cpu time: .1.3.6.1.4.1.2021.11.51.0

cpu number: .1.3.6.1.2.1.25.3.2

Memory Statistics

Total Swap Size: .1.3.6.1.4.1.2021.4.3.0
UCD-SNMP-MIB::memTotalSwap.0 = INTEGER: 489940 kB  


Available Swap Space: .1.3.6.1.4.1.2021.4.4.0
UCD-SNMP-MIB::memAvailSwap.0 = INTEGER: 284752 kB


Total RAM in machine: .1.3.6.1.4.1.2021.4.5.0
UCD-SNMP-MIB::memTotalReal.0 = INTEGER: 255672 kB


The available real memory: .1.3.6.1.4.1.2021.4.6.0
UCD-SNMP-MIB::memAvailReal.0 = INTEGER: 14456 kB


the Total free memory in the machine (free Swap memory + free RAM memory): .1.3.6.1.4.1.2021.4.11.0

UCD-SNMP-MIB::memTotalFree.0 = INTEGER: 298804 kB


Total RAM Shared: .1.3.6.1.4.1.2021.4.13.0
UCD-SNMP-MIB::memShared.0 = INTEGER: 0 kB


Total RAM Buffered: .1.3.6.1.4.1.2021.4.14.0
UCD-SNMP-MIB::memBuffer.0 = INTEGER: 2888 kB


Total Cached Memory: .1.3.6.1.4.1.2021.4.15.0
UCD-SNMP-MIB::memCached.0 = INTEGER: 47816 kB

Disk Statistics

The snmpd.conf needs to be edited. Add the following (assuming a machine with a single ‘/’ partition):

disk / 100000 (or)

includeAllDisks 10% for all partitions and disks

The OIDs are as follows

Path where the disk is mounted: .1.3.6.1.4.1.2021.9.1.2.1
Path of the device for the partition: .1.3.6.1.4.1.2021.9.1.3.1
Total size of the disk/partion (kBytes): .1.3.6.1.4.1.2021.9.1.6.1
Available space on the disk: .1.3.6.1.4.1.2021.9.1.7.1
Used space on the disk: .1.3.6.1.4.1.2021.9.1.8.1
Percentage of space used on disk: .1.3.6.1.4.1.2021.9.1.9.1
Percentage of inodes used on disk: .1.3.6.1.4.1.2021.9.1.10.1

System Uptime: .1.3.6.1.2.1.1.3.0



python snmp 從OID獲取對應的值

先安裝模塊 netsnmp

import netsnmp
session = netsnmp.Session( DestHost='your.host.com', Version=2, Community='public' )
vars = netsnmp.VarList( netsnmp.Varbind(oid) )
print( session.get(vars) )