一、準備
1.iDRAC開啓SNMP服務
2. 確保開啓snmp 和端口(116)
zabbix 服務端通過snmp驗證
snmpget -v 2c -c xkeshi ip .1.3.6.1.4.1.674.10892.2.1.1.2.0
SNMPv2-SMI::enterprises.674.10892.2.1.1.2.0 = STRING: "iDRAC8"
二、zabbix web配置
1、創建值映射
zabbix web界面 —> 管理 —> 一般 —> 值映射
將根據下列名稱進行值映射
DellDracDiskState
1 -> Unknown
2 -> Ready
3 -> Online
4 -> Foreign
5 -> Offline
6 -> Blocked
7 -> Failed
8 -> Non-RAID
9 -> Removed
Dell iDRAC Network Device Connection Status
1 -> Connected
2 -> Disconnected
Dell Open Manage System Status
1 -> Other
2 -> Unknown
3 -> OK
4 -> NonCritical
5 -> Critical
6 -> NonRecoverable
DellPowerState
1 -> Other
2 -> Unknown
3 -> Off
4 -> On
Dell PSU State Settings
1 -> Unknown
2 -> Online (state disabled)
4 -> not Ready
8 -> Fan Failure
10 -> Online and Fan Failure
16 -> On
242 -> Online and OK
DellRaidLevel
1 -> Unknown
2 -> RAID-0
3 -> RAID-1
4 -> RAID-5
5 -> RAID-6
6 -> RAID-10
7 -> RAID-50
8 -> RAID-60
9 -> Concatenated RAID 1
10 -> Concatenated RAID 5
DellRaidVolumeState
1 -> Unknown
2 -> Online
3 -> Failed
4 -> Degraded
Dell_PSU_SensorState
1 -> Presence Detected
2 -> PS Failure
4 -> Predictuve Failure
8 -> PS AC lost
16 -> AC lost or out of range
32 -> AC out of range but still present
2、配置全局變量{$SNMP_COMMUNITY_IDRAC}
zabbix web界面 —> 管理 —> 一般 —> 宏
3、導入模板
模板下載地址:https://github.com/endersonmaia/zabbix-templates/tree/master/dell/idrac
zabbix web界面 —> 配置 —> 模板 —> 導入
Template_Dell_iDRAC_SNMPv2.zbx.xml
4、創建主機
zabbix web界面 —> 配置 —> 主機 —> 創建主機
輸入主機地址及SNMP地址和端口,保存
5、利用grafana進行可視化配置
至此,所有操作步驟已經完成,你可以定義不同的圖形將所有的監控項進行整合,