Message Code Message String Message Comments Minimum Action Required to Remove Message from LCD
E1A10 PDBPwrCable PDB power cable to the planar is missing or bad and system will not power on. Failing device is reseated/replaced/repaired.
E1A11 PCIRsrConfig PCI risers are not configured correctly; some invalid configurations prevent system power on. Failing device is reseated/replaced/repaired.
E1A11 PCIRsrConfig PCI risers are not configured correctly; some invalid configurations prevent system power on. Failing device is reseated/replaced/repaired.
E1A12 PCIRsrMissing One or all of the PCI risers is missing. This prevents system power on. Failing device is reseated/replaced/repaired.
E1A14 SAS Cable A SAS cable A is missing or bad. Failing device is reseated/replaced/repaired.
E1A15 SAS Cable B SAS cable B is missing or bad. Failing device is reseated/replaced/repaired.
E1A16 SAS Cable FB Flex bay SAS cable is missing or bad. Failing device is reseated/replaced/repaired.
E1A17 PwrCable FB Flex bay power cable is missing or bad. Failing device is reseated/replaced/repaired.
E1A18 PDBCtrl Cable PDB control cable to the planar is missing or bad and system will not power on. Failing device is reseated/replaced/repaired.
E1114 Temp Ambient Ambient temperature has a reached a point outside of the allowed range. Temperature returns to allowable range.