華爲交換機恢復以前配置文件vrpcfg.cfg

一.以交換機爲ftp客戶端,登錄ftp服務器下載上次備份的配置文件到交換機上。

<BJ-md38-D2>ftp 61.139.126.XX
Trying 61.139.126.34 ...
Press CTRL+K to abort
Connected to 61.139.126.XX.
220-Microsoft FTP Service
220 歡迎你連接本站FTP!
User(61.139.126.34:(none)):XXXXX
331 Password required for westserver.
Enter password:
230-您已連接本站FTP服務器
230 User westserver logged in.

[ftp] get switch/BJIDC/2016-11-11-D02.zip       /下載之前備份的最後一次交換機配置文件vrpcfg.cfg

200 PORT command successful.

150 Opening ASCII mode data connection for switch/BJIDC/2016-11-11-D02.zip(1626 bytes). 226 Transfer complete.

FTP: 1626 byte(s) received in 3.900 second(s) 416.92byte(s)/sec.

[ftp]

二.退出ftp,設置恢復的配置文件爲下次啓動配置文件並重啓設備。

[ftp]q 221 再見..

dir Directory of flash:/                                        看一下剛下載的配置文件

Idx Attr Size(Byte) Date Time FileName

0 -rw- 969 Nov 05 2008 20:33:59 private-data.txt

1 -rw- 1,626 Nov 11 2016 17:19:49 2016-11-11-D02.zip

2 -rw- 1,089,840 Jan 01 1970 00:02:05 S5700SI-V100R005C01SPC100.web .zip

3 -rw- 10,215,068 Oct 01 2008 00:02:21 S5700SI-V100R005C01SPC100.cc

4 -rw- 626,426 Jan 01 1970 00:03:17 s27_37_57-v100r005sph008.pat

5 -rw- 12,240 Jan 01 1970 00:03:19 $_patchstate_reboot

6 -rw- 1,626 Jul 22 2016 11:51:46 vrpcfg.zip

31,620 KB total (19,924 KB free)

startup saved-configuration 2016-11-11-D02.zip     /下次重新啓動時選擇的要加載配置文件名。

display startup

reboot  