VSA是爲中小企業無共享存儲的環境設計的,最多官方推薦3臺ESXi主機構成,減少部署成本,但是官方報價7999美金,不免是一種遺憾!!但是技術依然是有意義的,特別是在中國這個特殊的IT版權環境下
The following illustration depicts failover in a VSA cluster with 3 members.
The total capacity of a VSA cluster is the sum of the capacities of all VSA datastores. A VSA cluster can have 2 or 3 VSA datastores.
In a VSA cluster with 4, 6, or 8 hard disks per ESXi host and a RAID10 configuration, the capacity of the VSA cluster depends on two variables.
■
|
|
■
|
The capacity of a VSA datastore equals the total hard disk capacity of the ESXi host divided by 4. This is due to the RAID10 configuration on each ESXi host and the mirroring of VSA volumes between VSA cluster members.
Determine the VSA datastore capacity by using the following formula.
VSA datastore capacity = hard disk capacity of an ESXi host / 4
hard disk capacity of an ESXi host = the total capacity of the hard disks that are installed internally on the ESXi host
If you create a VSA cluster with hosts that have different total hard disk capacities, the lowest hard disk capacity from all ESXi hosts becomes the basis for calculating the capacity of every VSA datastore. In such a situation, some of the total hard disk capacity remains unused.