Storcli常用命令


目前LSI RAID卡使用的配置工作主要有:Megaraid Storage ManagerMSM,圖形環境)MegaCLI(字符界面)、StorCLI(字符界面)。其中StorCLI整合了LSI和原來3ware的產品支持,相對MegaCLI命令更加簡潔,並且兼容MegaCLI的命令,估計不久的將來兩者會統一


一、環境

Manufacturer: Dell Inc.

Product Name:PowerEdge R720

Model = PERCH710 Mini

Centos6.4 x64,2.6.32-358.el6.x86_64

Storage Command Line Tool Ver 1.03.46 Aug 16, 2013


二、句法

The StorCLI syntax uses thefollowing general format:

[object identifier]> <verb><[adverb | attributes | properties] > <[key=value]>


三、Raid卡命令

cd /opt/MegaRAID/storcli/

./storcli64 show [all]顯示raid卡相關信息、raid卡高級軟件信息

./storcli64 /cx show all 顯示某一塊raid卡的版本、功能、狀態、以及raid卡下的物理磁、邏輯盤信息

./storcli64 /cx show freespace 顯示剩下的磁盤空間

./storcli64 /cx set rebuildrate=x 整數,設置rebuildrate速度

./storcli64 /cx show rebuildrate

./storcli64 /cx set patrolread=on or off 開啓或關閉patrolread

./storcli64 /cx show patrolread

./storcli64 /cx set cc=on or off 開啓或關閉rate

./storcli64 /cx show cc

./storcli64 /cx show ccrate

./storcli64 /cx download file=filepath 升級raid卡固件,需要重啓

./storcli64 /cx flushcache 清除raid卡、物理磁盤cache


四、物理磁盤命令

./storcli64 /cx/eall/sall show 顯示物理磁盤信息

./storcli64 /cx/eall/sall show all 顯示詳細物理磁盤信息

./storcli64 /cx/ex/sx set good/offline/online/missing 設置某塊磁盤的狀態

./storcli64 /cx/ex/sx start locate 定位某塊磁盤

./storcli64 /cx/ex/sx stop locate

./storcli64 /cx/ex/sx show rebuild 查看rebild

./storcli64 /cx/ex/sx start rebuild

./storcli64 /cx/ex/sx stop rebuild

./storcli64 /cx/ex/sx add hostsparedrive dgs=x 設置模塊磁盤爲diskgroup x 的熱備盤

./storcli64 /cx/ex/sx delete hostsparedrive

五、邏輯磁盤命令

增加邏輯磁盤的命令:(選項很多,較複雜)163844779.png



163930776.png

163932433.png



Eg./storcli64 /c0 add vd type=raid5 size=all names=tmp1 drives=32:2-4

./storcli64/c0 add vd type=raid10 size=all names=tmp1 drives=32:2-7 pdperarray=2 創建10/50/60時,必須制定pdperarray參數

創建多個邏輯分區時:./storcli64/c0 add vd type=raid10 size=100GB,200GB names=tmp1,tmp2 drives=32:2-7pdperarray=2;剩下的空間:./storcli64 /c0 add vd type=raid10 size=all names=tmp3 drives=32:2-7pdperarray=2,需要注意,此時其餘的參數要和之前的一致,否則報錯

./storcli64 /c0/v1set wrcache=wt

./storcli64 /cx/vx/vallshow 顯示邏輯磁盤信息

./storcli64 /cx/vx/vall show all 顯示邏輯磁盤信息

./storcli64 /cx/vx/valldel 刪除邏輯磁盤,此命令會等待cache中的數據寫入磁盤

./storcli64 /cx/vx/vall del force刪除邏輯磁盤,此命令不會等待cache中的數據寫入磁盤

設置vd屬性的命令:

163934490.png


Raid 轉換命令:(集成的raid卡不支持該命令)

./storcli64 /cx/vx/vall show migrate

./storcli64 /cx/vx/vall start migrate type=raid x [option=add/removedisk=xx]

Eg: ./storcli64 /c0/v1 start migrate type=r5 option=removedisk=e32:s6,e32:s7


164004513.png

./storcli64 /cx/vx/vall show cc 一致性檢查

./storcli64 /cx/vx/vall start cc

./storcli64 /cx/vx/vall stop cc


./storcli64 /cx/vx/vall set wrcache=wt/wb/awb 設置寫策略



六、外部磁盤命令

./storcli64 /cx/fx/fall del

./storcli64 /cx/fx/fall import

./storcli64 /cx/fx/fall show


七、BBU命令

./storcli64 /cx/bbu show

./storcli64 /cx/bbu show all

./storcli64 /cx/bbu set bbumode=x (默認爲0

164027643.png

八、其他常用命令

./storcli64 -v 顯示版本

./storcli64 -h 顯示幫助信息

./storcli64 show [all] 顯示raid卡信息

./storcli64 /cx show freespace 顯示剩餘空間

./storcli64/cx/vx/vall show[all] 顯示邏輯磁盤信息

./storcli64 /cx/vx/vall set wrcache=wt/wb/awb 設置寫策略


發表評論
所有評論
還沒有人評論,想成為第一個評論的人麼? 請在上方評論欄輸入並且點擊發布.
相關文章